{"id":82,"date":"2017-12-11T16:18:40","date_gmt":"2017-12-11T20:18:40","guid":{"rendered":"http:\/\/sites.nd.edu\/nicu-design-std-kjsk\/?p=82"},"modified":"2017-12-11T16:18:40","modified_gmt":"2017-12-11T20:18:40","slug":"substantive-changes-8th-edition","status":"publish","type":"post","link":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/2017\/12\/11\/substantive-changes-8th-edition\/","title":{"rendered":"Substantive Changes &#8211; 8th Edition"},"content":{"rendered":"<p><em><u>General changes:<\/u><\/em>\u00a0 The Standards have been re-numbered to allow similar topics to be positioned together in the document.<\/p>\n<p><em><u>Standard 5:<\/u><\/em>\u00a0 This Standard now explicitly states that space must be provided at the bedside to allow for extended, intimate parental contact with the infant.<\/p>\n<p><em><u>Standard 6:<\/u><\/em>\u00a0 The minimum clear floor space for single patient rooms has been increased to 165 square feet, based on extensive experience with NICUs that have incorporated this feature and found that rooms any smaller than this are universally considered to be too small.\u00a0 The Standard now also specifies that a recumbent sleep surface be provided for at least one adult in these rooms.<\/p>\n<p><em><u>Standard 11:<\/u><\/em>\u00a0 In light of the efficacy and increased use of waterless hand cleansers, the requirement that each single patient room have a handwashing station has been removed.\u00a0 Each patient bed must still be within 20 feet of a handwashing sink so most designers will choose to place a sink inside a private room, but this change gives designers the option of situating the sink just outside the room based on their evaluation of the benefits and disadvantages of having a sink within the patient room.<\/p>\n<p><em><u>Standard 14:<\/u><\/em>\u00a0 Unless provided elsewhere in the hospital, space must be provided in the NICU for feeding preparation, which should no longer be performed at the bedside.<\/p>\n<p><em><u>Standard 22:<\/u><\/em>\u00a0 A requirement has been added to describe the allowable level of flicker in luminaires.<\/p>\n<p><em><u>Standards 25 and 26:<\/u><\/em>\u00a0 The requirements for daylighting and access to nature have been clarified so that it will be clear that windows are not required for each patient room.\u00a0 Our intent is to assure that daylighting and access to nature are readily accessible to families and staff.\u00a0 These features are acceptable, even desirable in private rooms, but designers should not strive to provide windows in each private room if this means being unable to provide them in spaces frequented by adult caregivers and families.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>General changes:\u00a0 The Standards have been re-numbered to allow similar topics to be positioned together in the document. Standard 5:\u00a0 This Standard now explicitly states that space must be provided at the bedside to allow for extended, intimate parental contact &hellip; <a href=\"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/2017\/12\/11\/substantive-changes-8th-edition\/\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1144,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[273573],"tags":[],"class_list":["post-82","post","type-post","status-publish","format-standard","hentry","category-report-of-the-8th-consensus-committee"],"_links":{"self":[{"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/posts\/82","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/users\/1144"}],"replies":[{"embeddable":true,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/comments?post=82"}],"version-history":[{"count":1,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/posts\/82\/revisions"}],"predecessor-version":[{"id":83,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/posts\/82\/revisions\/83"}],"wp:attachment":[{"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/media?parent=82"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/categories?post=82"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sites.nd.edu\/nicu-design-std-kjsk\/wp-json\/wp\/v2\/tags?post=82"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}